Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuroradiology ; 52(7): 611-8, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20309532

RESUMO

INTRODUCTION: The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. METHODS: We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. RESULTS: The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. CONCLUSION: Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable.


Assuntos
Artérias Carótidas/cirurgia , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/instrumentação , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/complicações , Estenose das Carótidas/mortalidade , Estenose das Carótidas/cirurgia , Feminino , Seguimentos , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/métodos , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...